<< Click to Display Table of Contents >> Navigation: Plate Recognition > LPR Zones > LPR zone events |
The LPR Zones system has events that can be triggered according to the conditions of entry or exit of a vehicle:
•Trigger event when a vehicle remains in the zone for the configured time: This option will trigger the configured actions if a license plate is captured at the input and is not captured at the output after the defined X minutes.
•Trigger event when a vehicle leaves the zone before the configured time: This option will trigger the configured actions if a license plate is captured at the input and is captured at the output before the defined X minutes.
•Trigger event when a vehicle leaves the zone after the configured time: This option will trigger the configured actions if a license plate is captured at the output after X minutes of capturing the input.
•Trigger event when a vehicle enters the zone X times in Y minutes: This option will trigger event actions when a vehicle enters and leaves the zone many times in a short period of time. In the example above, the event would be triggered if the same license plate was recognized entering the zone twice in less than 60 minutes.
•Event Actions: Desired alarm actions when the event is triggered. To learn more about event actions, see the chapter How to configure event actions.